Adequate hot water supplied by a leak free, safe, durable, efficient, and accessible water heater
Specifications
- SF
- MH
- MF
Specification | Objective |
---|---|
Verify current plumbing infrastructure is sufficient to support the installation(s) and is leak-free If a roof installation is planned, verify that the roof will support the installation (e.g., dead load, wind load) and that the current roof has more than 10 years of useful life remaining |
Verify adequacy of plumbing |
- SF
- MH
- MF
Specification | Objective |
---|---|
Select a storage/backup water heaters that: is ENERGY STAR® certified, equivalent, or better fits in the installation space with required clearances provides sufficient hot water for the home and occupants is insulated to R-12.5 or greater |
Efficient, and appropriate tank selected |
- SF
- MH
- MF
Specification | Objective |
---|---|
Locate solar collectors to minimize shading factor and maximize solar gain, but not interfere with other appliance operation (e.g., chimneys, vents, exhaust terminations) |
Maximize system performance |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install and plumb storage tank and solar collectors to allow for inspection, maintenance, and replacement of the appliance and its components Ensure that anode rod is accessible for replacement Provide a path that allows the solar collector to be safely accessed without damaging the roof |
System is safely accessible for service |
- SF
- MH
- MF
Specification | Objective |
---|---|
Incorporate system freeze protection for applicable climates, including, but not limited to, closed glycol loops, drain back systems, supplemental heat, or other methods, as approved by applicable code and manufacturer specifications |
Prevent freezing liquid in pipes in cold weather climates |
- SF
- MH
- MF
Specification | Objective |
---|---|
If appliance is installed in or above conditioned space or in a location where water damage could occur, install a drain pan according to the requirements of the IRC Drain pan to the exterior of the building |
Prevent water damage from leaking water |
- SF
- MH
- MF
Specification | Objective |
---|---|
Direct scalding water away from occupants |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install dielectric unions when connecting copper to galvanized steel piping in accordance with the IRC and manufacturer specifications |
Prevent corrosion between dissimilar metals |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install heat traps on the inlet and outlet piping where not provided by manufacturer |
Reduce thermal loss from convection or siphoning |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install a separate water cut-off valve for both the hot and cold incoming water lines at the storage tank, and between each additional components of the system (e.g., mixing valves, solar collector, additional storage tank) |
Allow isolation and service of each system component |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install an expansion tank anytime a storage water heater is supplied with cold water that passes through a check valve, pressure reducing valve or backflow preventer Connect the tank to the cold water supply line at a point that is downstream of all check valves, pressure reducing valves and backflow preventers Size thermal expansion tanks in accordance with the tank manufacturer's instructions and applicable code (e.g., IRC, IBC) |
Protect tank and connected piping from expansion damage or leaks |
- SF
- MH
- MF
Specification | Objective |
---|---|
Insulate all accessible pipes carrying hot water to a minimum R-3 per SWS (Water Heating: Thermal Loss Reduction: Pipe Insulation" |
Reduce heat loss through hot water pipes |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install a suitable thermostatic mixing valve and set discharge temperature to not exceed 120 degrees or as prescribed by local code Install a temperature-indicating device at the discharge outlet of the thermostatic mixing valve |
Prevent biological growth in tank but prevent scalding |
- MF
Specification | Objective |
---|---|
In multitank systems, install valves to isolate each tank from water heating system and install bypass piping |
Allow removal and maintenance of a single tank without shutting down entire system |
- SF
- MH
- MF
Specification | Objective |
---|---|
Permanently remove equipment from job site and recycle or dispose of removed equipment and refrigerant in accordance with local and federal law (e.g., EPA Section 608 of Clean Air Act of 1990) Permanently decommission old equipment |
Old equipment is permanently removed from service, protect the environment, and comply with regulation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Provide occupants/owners with user's manual, warranty information, installation instructions, and installer contact information |
Manufacturer supplied information available to occupant |