Continuous, contiguous, and safe thermal boundary that prevents air movement @ 50 Pascals
Specifications
- SF
- MF
Specification | Objective |
---|---|
Verify that installation area is free of: active water leaks, fuel leaks (i.e., gas, oil, propane), and pest intrusions energized knob and tube wiring uncovered electrical junctions improperly terminated devices (ventilation fans, dryers, plumbing stacks, condensate lines, combustion appliance flues/chimneys, etc.) unshielded high-temperature devices (non-IC rated recessed lights, chimneys, flues, vents, etc.) unless they are zero clearance devices insulation escape openings Verify that installation area is: intact, able to support insulation weight, and air sealed |
Ensure space can be safely insulated |
- SF
- MF
Specification | Objective |
---|---|
Prevent condensation and provide fire safe assembly |
- SF
- MF
Specification | Objective |
---|---|
Remove any existing insulation or vapor barrier materials and protrusions from installation area |
Prevent condensation, uninterrupted installation area |
- SF
- MF
Specification | Objective |
---|---|
Install rigid insulation to prescribed R-value in every joist bay in full contact with the rim/band joist air barrier and all sides of the cavity without gaps, voids, or misalignments Install rigid insulation to prescribed R-value in every joist bay in full contact with the rim/band joist air barrier and all sides of the cavity without gaps, voids, or misalignments |
Continuous and contiguous thermal boundary Continuous and contiguous thermal boundary |
- SF
- MF
Specification | Objective |
---|---|
Seal each cavity airtight around the perimeter of the rigid insulation |
Prevent air and moisture movement in cavity |
- SF
- MF
Specification | Objective |
---|---|
If foam is no more than 3 1/4" thick and the space is not permanently habitable no thermal barrier is required If foam is thicker than 3 1/4", doesn't meet the flame and smoke index, or is of less than 0.5 lb/ft3 density, or the space is permanently habitable, separate foam from the subspace with a suitable thermal barrier covering or coating as indicated in manufacturer's specifications and applicable building code If code requirements are unclear, consult local code officials for clarification |
Minimize ignition and combustion potential |
- SF
- MF
Specification | Objective |
---|---|
Post a dated receipt signed by the installer that minimally includes: Installed insulation type, coverage area, installed thickness, and installed R-value |
Comply with 16 CFR 460.17 and document contract compliance |