Durable, safe, and effective, renewable energy installation
Specifications
- SF
- MH
- MF
Specification | Objective |
---|---|
Verify current electrical panel and service line infrastructure is in good condition, compliant with codes, and of sufficient electrical capacity (Amps) to accommodate interconnection of solar power. Verify position of spare (unused) breaker or space to install new breaker in panel for solar power interconnection If a roof installation is planned, verify that the roof will support the installation (e.g., dead load, wind load) and that the current roof covering is less than 5 years old. Verify that the type of roof is suitable for solar installation (e.g. not slate or wood shingle). The roof understructure shall be inspected and evaluated for support of PV system. Any reinforcements, such as blocking between rafters, shall be completed before load of PV system is applied If a roof installation is planned, the roof shall be inspected, cleaned and any necessary repairs shall be made |
Adequate structural and electrical to support PV install |
- SF
- MH
- MF
Specification | Objective |
---|---|
Design the size of PV system to serve the prescribed load Prepare electrical one line drawing Prepare layout drawings showing location and connections of all equipment Provide list (make, model) of all equipment Design PV system layout to provide safe access around PV modules as required by codes and standards, and required clearances around balance-of-system components such as inverter and switchgear Locate PV Modules to minimize shading factor and maximize solar gain, but not interfere with existing systems or appliance operation (e.g., chimneys, vents, exhaust terminations) |
Maximize PV system performance |
- SF
- MH
- MF
Specification | Objective |
---|---|
Secure approval of design by utility and secure interconnection agreement to operate utility-connected PV system |
Obtain utility-connected system interconnection agreement |
- SF
- MH
- MF
Specification | Objective |
---|---|
Secure electrical permit to install and operate PV system from Authority Having Jurisdiction (AHJ) (e.g. County building Dept.) |
Obtain required permits for PV installation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Installer shall meet the requirements of AHJ |
Select qualified installers |
- SF
- MH
- MF
Specification | Objective |
---|---|
Secure the mounting structures to the roof following manufacturer instructions Install flashing to make all roof penetrations weather-tight and leak-proof using instructions and materials specified by manufacturer Install inverters and disconnects in a safe and accessible location, inverter shall be located in the shade when specified by manufacturer's instructions Install solar panels on the mounting structures according to the manufacturer's instructions |
Watertight, safe, wind-resistant, and compliant roof-mounted equipment installation |
- SF
- MH
- MF
Specification | Objective |
---|---|
The installation shall comply with all applicable codes and standards adopted by Authority Having Jurisdiction, including but not limited to: National Electric Code (NEC) International Residential Code (IRC) IEEE 1547 Standard for Interconnecting Distributed Resources with Electric Power Systems UL 1703 Standard for Flat-Plate Photovoltaic Modules and Panels Manufacturer's installation and operation manuals If conflict exists between code and manufacturer specifications, apply the more restrictive requirement |
Compliant and safe installation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install PV Array and Balance of System to allow for inspection, maintenance, and replacement of the PV system components Provide a path that allows the PV modules to be safely accessed without damaging the roof or PV modules |
System safely accessible for service |
- SF
- MH
- MF
Specification | Objective |
---|---|
Install all electrical components according to the NEC and authority having jurisdiction Fasten wires with wire ties and conduit as per design and installation instructions The system shall be connected to the electrical grid at a location and in a method approved by the utility If a conflict exists, the most restrictive rule applies |
Safely installed interconnected electrical system |
- SF
- MH
- MF
Specification | Objective |
---|---|
Monitor the system energy delivery for a minimum of 12 months and compare results with predicted energy production |
Validate system performance |
- SF
- MH
- MF
Specification | Objective |
---|---|
Provide documentation to the building owner, including: copy of the installation and operation manual electrical diagrams and schematics certificate of inspection and approval system performance benchmark data |
Facilitate ongoing maintenance and repairs |
- SF
- MH
- MF
Specification | Objective |
---|---|
Inspect the installation as required by the AHJ |
Third-party verification of installation safety and operation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Perform electrical tests to verify proper operation and system performance Tests include open circuit voltage, operating current, resistance of grounding system (should be <25 ohms), and resistance of electrical insulation (should be >1 Megohm) Measured voltage shall be compared to reference voltage corrected for temperature Measured current shall be compared to reference current corrected for insolation (sunlight level) |
Verify proper operation and system performance |
- SF
- MH
- MF
Specification | Objective |
---|---|
Clear jobsite of construction waste Permanently remove all waste materials from job site and recycle or dispose of removed materials in accordance with local and federal law |
Old equipment is permanently removed from service, protect the environment, and comply with regulation |
- SF
- MH
- MF
Specification | Objective |
---|---|
Provide occupants/owners with user's manual, warranty information, installation instructions, and installer contact information |
Manufacturer supplied information available to occupant |
- SF
- MH
- MF
Specification | Objective |
---|---|
The PV modules and inverter shall be warranted by the manufacturer Whole system shall be warranted by the installer for a period of at least 1 year The warranty shall cover defects in materials and workmanship |
Ensure performance of the installed system |